A biomedical equipment maintenance programme is a planned system for keeping every medical device in a facility or state safe, accurate and available. It rests on a complete tagged inventory, scheduled inspection and preventive maintenance, prompt corrective repair, calibration and safety testing, and indicators such as uptime that are reviewed regularly. In India, the National Biomedical Equipment Management and Maintenance Programme (BMMP) under the National Health Mission provides the framework and the targets.
Why maintenance needs a programme, not just a repair budget
WHO's Medical device technical series treats maintenance as a strategy that combines inspection with preventive and corrective maintenance, rather than a response to breakdowns[1]. India's 2024 guidelines from the National Health Systems Resource Centre (NHSRC) set out the aim plainly: maximum availability with minimum downtime, higher reliability, longer equipment life, less waste of consumables and spares, and better return on investment[2].
The cost of not doing this is visible in the data. A study of inventories from hospitals in 16 countries found that, on average, 38.3% of equipment in developing countries was out of service, with lack of training, health technology management and infrastructure as the main causes[3]. When MoHFW issued the BMMP guidelines in 2015, it noted evidence that 30% to 60% of medical equipment was non-functional in different states[4]. The later national mapping covered about 7.57 lakh items in 29,115 facilities across 29 states, valued at roughly ₹4,564 crore, and found 13% to 34% non-functional depending on the state[5]. Writing about medical oxygen, the Lancet Global Health Commission warned that funding equipment without the people and systems to maintain it creates "device graveyards"[6].
India's BMMP in brief
The BMMP has operated since 2015, with NHM funding for equipment maintenance provided to states and UTs through their annual Programme Implementation Plans (PIPs)[2]. States can deliver it in public-private partnership (PPP) mode, outsourcing to a service provider, or in-house, using OEM annual or comprehensive maintenance contracts; NHSRC reports it operational in 30 states and UTs[2].
The 2015 model framework for the PPP route set out the core service package[4]:
- Maintenance of biomedical equipment in all public facilities down to PHC level, backed by a 24x7 call centre with a toll-free number for registering faults.
- Uptime of 95% in district hospitals, 90% in CHCs and 80% in PHCs, with no single breakdown lasting more than seven days from registration.
- Substitute equipment within 12 hours once downtime exceeds the permissible 1.5 days a month.
- Penalties for missed thresholds, suggested at twice the comprehensive maintenance cost of the equipment for the period it was down.
- Contracts of three to five years, extendable to seven.
Whatever the mode, NHSRC stresses that biomedical engineers and technicians are needed at district and facility level, and notes that IPHS-2022 recommends a biomedical engineer post in district hospitals[2]. It describes three levels of maintenance: day-to-day care by the operator, work by the in-house biomedical engineer, and service by OEM-trained engineers[2].
Step one: inventory, tagging and categorisation
WHO positions inventory management as the foundation of a maintenance programme, in a set of three companion documents covering inventory, maintenance and computerised maintenance management[7]. You cannot plan maintenance, budget spares or measure uptime for equipment you have not listed.
The BMMP model work order expects the service agency to map the full inventory, which includes giving every item an asset identification number, managing documents such as invoices, warranties and safety reports, recording maintenance activity and producing periodic status reports[4]. NHSRC recommends a single master asset register with standard classifications, kept online rather than on paper, and names centralised applications such as e-Upkaran[2]. Where a private provider runs the IT dashboard, the state health society should retain administrative control of the dashboard and custody of the server holding BMMP data[2].
Categorisation sets maintenance priorities. NHSRC suggests three groups: sophisticated electromedical equipment that needs the OEM and imported spares; "plug and play" electromedical equipment that in-house engineers or the service provider can fix with locally available parts; and non-electromedical equipment that rarely fails[2]. MoHFW's list of critical life-saving equipment includes ventilators, defibrillators, infusion pumps, multiparameter monitors, anaesthesia machines, oxygen concentrators, haemodialysis machines, haematology and biochemistry analysers, X-ray and ultrasound machines and radiant warmers[2]. Under IPHS-2022 there are 31 critical items on the district hospital list, 21 at a CHC and 5 at a PHC[2].
Preventive and corrective maintenance
NHSRC defines preventive maintenance as work done at set intervals or to the manufacturer's recommendation to reduce the chance of failure, and corrective (breakdown) maintenance as work done after a fault is recognised to restore function[2]. Its practical rules include:
- Carry out preventive maintenance on all equipment held, whether in use or not, so its status is always known[2].
- Inspect life-saving equipment in casualty, ICU and OT daily and keep a standby unit ready[2].
- When a fault occurs, label the device so no one else uses it, record the details and log the complaint on the provider's or OEM's toll-free line[2].
- Users should do visual checks, power-on and performance tests as the manufacturer instructs and record them in the equipment logbook[2].
NHSRC also suggests preventive maintenance and calibration visit frequencies for equipment listed under IPHS-2022. A selection[2]:
| Equipment | Suggested PM and calibration visits per year |
|---|---|
| Ventilators (adult, paediatric, neonatal) | 4 |
| Multiparameter and cardiac monitors | 4 |
| Infusion pumps | 4 |
| Dialysis machines | 4 |
| Haematology analysers (3-part and 5-part) | 4 |
| Fixed X-ray machines and C-arms | 4 |
| Ultrasound machines | 4 |
| Defibrillators | 2 |
| Syringe pumps | 2 |
| Mobile 100 mA X-ray | 2 |
| Centrifuges | 2 |
| Oxygen concentrators | 2 |
The equipment audit then closes the loop. NHSRC lists common reasons for dysfunctional equipment, including minor repairs left undone, missed preventive or corrective maintenance, missing spares, electrical faults, mishandling by untrained staff, and equipment bought without a justified need[2].
Calibration and electrical safety testing
Calibration confirms that a device measures or delivers what it displays, against traceable standards. NHSRC notes that intervals depend on instrument type, manufacturer advice, usage, criticality, environment, required accuracy and regulatory requirements, and advises facilities to set schedules with manufacturers and experts[2]. Calibration certificates should state the associated measurement uncertainty[2].
India's traceability chain runs from CSIR-National Physical Laboratory, the national metrology institute, through calibration laboratories accredited by NABL to ISO/IEC 17025, which include a medical devices discipline[2]. STQC laboratories under MeitY also offer medical equipment calibration[2]. The BMMP framework asks for an annual audit of the service provider's calibration processes by an NABL or ILAC-accredited laboratory, including calibration of the provider's own test tools, and for special attention to alarm function and electrical safety during testing[4].
For electromedical equipment, NHSRC lists checks made with an electrical safety analyser, including insulation resistance and leakage currents to earth, through the enclosure and through the patient[2]. The international reference for these routine checks is IEC 62353, which covers recurrent testing and testing after repair of medical electrical equipment[8]. Laboratory analysers carry additional quality requirements, covered in our article on calibration under ISO 15189, and X-ray equipment has AERB quality assurance obligations, covered in AERB requirements for diagnostic X-ray.
Uptime targets and key performance indicators
BMMP measures two headline indicators for PIPs[2]:
- Maintenance coverage: equipment under warranty, CAMC or AMC as a percentage of all equipment in the inventory.
- Uptime: equipment found functional at census as a percentage of the inventory, against targets of 80% at PHCs, 90% at CHCs and 95% at district hospitals.
The 2015 guidelines describe 95% uptime over a year as a reflection of good systems efficiency, and point out that it still allows about 18 days of downtime a year, too long at a stretch for life-saving equipment, which is why the permissible downtime was set per month[4].
Uptime alone can hide problems, so mature programmes add operational indicators. WHO notes that a computerised maintenance management system typically tracks performance indicators alongside service history, preventive maintenance procedures and costs[9]. A practical set:
| Indicator | What it shows |
|---|---|
| Uptime by facility level and by critical equipment | Availability against BMMP targets |
| Contract coverage | Share of assets with a warranty, AMC or CMC |
| Preventive maintenance completion | Scheduled visits done on time |
| Response time and time to restore | Speed of the service chain after a call |
| Repeat failures within a set period | Quality of repairs and root-cause analysis |
| Calibration compliance | Devices with a valid calibration or safety test |
| Maintenance cost as a percentage of asset value | Affordability and value for money |
Computerised maintenance management
A CMMS turns the programme into data. WHO describes it as a tool to improve equipment management at facility level that always contains the inventory and usually service history, preventive maintenance procedures, performance indicators and costing[9]. In 2025 WHO published updated guidance on inventory and maintenance management information systems for medical devices[10]. When choosing or procuring a system, look for unique asset IDs, mobile complaint logging with time stamps, automatic preventive maintenance scheduling, calibration due-date alerts, spares tracking and dashboards that report BMMP indicators by facility, with the state retaining data ownership.
Outsourcing and contracting models
NHSRC compares the main contract types[2]:
| Contract | Scope | Charges |
|---|---|---|
| Warranty | Full service with parts or replacement; quick response | Usually built into the purchase price |
| Comprehensive maintenance contract (CMC) | Service plus minor spares and consumables, by OEM or third party | Service charges include these parts |
| Annual maintenance contract (AMC) | Service only, starting after warranty, by OEM or third party | Fixed annual fee; spares billed separately |
For specialised and life-saving equipment, NHSRC recommends a CMC that includes all spares, and suggests buying such equipment with two years' warranty followed by eight years' CMC at rates fixed in the original tender[2]. Renewal of any contract should start three months before the current one expires[2].
On cost, the 2015 BMMP guidelines estimated comprehensive maintenance at about 2% to 5% of asset value for less complex equipment and 7% to 12% for highly complex equipment, averaging 5% to 10% for a mixed group, depending on spares imports, engineering costs, software and competition[4].
The models can be combined: for example, an outsourced comprehensive contract for the bulk of plug-and-play equipment, OEM CMCs for imaging and other sophisticated systems, and an in-house team for first-line response, user training and contract supervision. NHSRC recommends a Hospital Equipment Management Committee, including the medical superintendent, clinical heads, biomedical engineer, stores, finance and nursing, that meets at least quarterly to oversee the provider, review downtime and logs, run the annual census and recommend condemnation of equipment beyond economic repair[2].
Getting started
- Run a baseline census and tag every asset.
- Categorise equipment and identify critical items per facility level.
- Collect warranties, contracts and manuals; flag expiry dates.
- Set a preventive maintenance and calibration calendar from OEM guidance and NHSRC frequencies.
- Choose the delivery model and write contracts with uptime, response, substitution and penalty clauses.
- Set up the call centre or complaint line and the CMMS.
- Train users and review KPIs monthly and through the equipment committee.
How GKS Healthsol can help
GKS Healthsol provides capacity building and maintenance services for biomedical equipment, cold chain equipment and PSA oxygen plants. Its services cover gap assessment, user and technician training, asset tagging, calibration and testing, preventive maintenance, breakdown repair, a dedicated call centre and OEM spares management. GKS maintains more than 400 PSA oxygen plants in Rajasthan, Odisha, Jharkhand and Maharashtra under the PATH and USAID RISE programme, and has supplied, installed and supported 150 X-ray machines across 25 states for CMSS under the National TB Elimination Programme. To scope a programme for your facilities, contact GKS.
Key takeaways
- A maintenance programme combines inventory, preventive and corrective maintenance, calibration and indicators; it is not just a repair budget.
- India's BMMP, funded through NHM PIPs since 2015, targets uptime of 95% at district hospitals, 90% at CHCs and 80% at PHCs.
- Start with a tagged, categorised master asset register held in a CMMS whose data the state owns.
- Use NABL-accredited calibration and IEC 62353-style electrical safety testing, with uncertainty stated on certificates.
- Match the contract model to the equipment: CMC for critical and complex devices, AMC or PPP for the wider base, with an in-house team supervising.
Frequently asked questions
BMMP is the National Biomedical Equipment Management and Maintenance Programme, operating since 2015. NHM funds states and UTs through their annual Programme Implementation Plans to keep public health facility equipment functional, either by outsourcing to a service provider in PPP mode or in-house through OEM maintenance contracts, with uptime targets set for each facility level.
BMMP guidelines set equipment uptime targets of 95% in district hospitals, 90% in community health centres and 80% in primary health centres. Uptime is measured as the share of inventoried equipment found functional at census. The 2015 model framework also limits any single breakdown to seven days and requires substitute equipment when downtime runs long.
An annual maintenance contract covers service visits and repairs for a fixed yearly fee, with spare parts billed separately. A comprehensive maintenance contract includes service plus spares and consumables within the charge. NHSRC recommends comprehensive contracts with all spares included for specialised and life-saving equipment, ideally fixed at purchase alongside the warranty.
There is no single interval. It depends on the device type, manufacturer recommendation, how heavily it is used, its criticality, the environment and regulatory requirements. NHSRC publishes suggested preventive maintenance and calibration frequencies for IPHS equipment, often two or four visits a year, and advises confirming schedules with manufacturers and NABL-accredited calibration laboratories.
A unique asset number links each device to its location, purchase records, warranty, contract, service history and calibration status. Without it, facilities cannot schedule preventive maintenance reliably, verify a provider's invoices, calculate uptime or decide when to condemn equipment. BMMP inventory mapping requires an asset identification number for every item.
References
- World Health Organization. Medical equipment maintenance programme overview. WHO Medical device technical series. WHO; 2011. https://www.who.int/publications/i/item/9789241501538
- National Health Systems Resource Centre (MoHFW). Guidelines on Equipment Maintenance, Calibration & Testing. NHSRC; 2024. https://nhsrcindia.org/sites/default/files/2025-01/Guidelines%20on%20Equipment%20Maintenance%2C%20Calibration%20and%20Testing.pdf
- Perry L, Malkin R. Effectiveness of medical equipment donations to improve health systems: how much medical equipment is broken in the developing world? Med Biol Eng Comput. 2011;49(7):719-722. https://doi.org/10.1007/s11517-011-0786-3
- National Health Mission, Ministry of Health and Family Welfare. Biomedical Equipment Management and Maintenance Program (guidelines and model RFP). MoHFW/NHSRC; 2015. https://nhsrcindia.org/sites/default/files/2021-05/Biomedical-Equipment-Revised-(10-02-2015).pdf
- National Health Systems Resource Centre. Biomedical Equipment Management and Maintenance Program (BEMMP). NHSRC. https://nhsrcindia.org/bemmp
- Graham HR, King C, Rahman AE, et al. Reducing global inequities in medical oxygen access: the Lancet Global Health Commission on medical oxygen security. Lancet Glob Health. 2025;13(3):e528-e584. https://doi.org/10.1016/S2214-109X(24)00496-0
- World Health Organization. Introduction to medical equipment inventory management. WHO Medical device technical series. WHO; 2011. https://www.who.int/publications/i/item/9789241501392
- International Electrotechnical Commission. IEC 62353:2014 Medical electrical equipment: Recurrent test and test after repair of medical electrical equipment. IEC; 2014. https://webstore.iec.ch/en/publication/6913
- World Health Organization. Computerized maintenance management system. WHO Medical device technical series. WHO; 2012. https://www.who.int/publications/i/item/9789241501415
- World Health Organization. Inventory and maintenance management information system for medical devices. WHO; 2025. https://www.who.int/publications/i/item/9789240111257
Sources accessed November 2026. Standards, regulations and clinical guidelines are revised periodically; always check the current edition. This article is for information and is not medical, legal or regulatory advice.